Indoor Outdoor Loose Tube Riser Rated Fiber Optic Wire Cable
Type OFNR, CSA
|
- Interbuilding and intrabuilding voice or data communication backbones
- Installed in ducts, underground conduits or aerial lashed CONSTRUCTION
Fiber:
|
- Dry loose tube with super-absorbent
polymer
- Color-coding per ITA/EIA 598B |
Jacket:
|
- Sequential footage markings
|
Central Strength Member:
|
- Epoxy/glass rod
|
Overall Strength Member:
|
- Aramid fiber yarn
|
- Dry loose tube for ease of termination
- Riser rated for indoor applications
Performance:
Temperature:
- Storage -40°C (-40°F) to +70°C (+158°F)
- Operating -20°C (-4°F) to +70°C (+158°F)
Minimum Bend Radius:
- 20 x OD - Installation
- 10 x OD - In-service
Maximum Crush Resistance:
- 150lbs./in.
- Maximum Vertical Rise - 1,640 ft.
Applications:
- Interbuilding and intrabuilding voice or data communication backbones
- Installed in ducts, underground conduits or aerial/lashed
- ETL Listed Type OFNR for installation in vertical riser and general horizontal applications when installed in accordance with NEC article 770-51 (b) and 770-53 (b)
Compliances:
ETL and c(ETL) Listed Type OFNR
- ICEA S-104-696
EMAIL US. REQUEST A QUOTE.
|
|
|
|
Part#
|
Fiber Count
|
Nom. O.D. Approx.
|
LBS./M'
|
44Fxx06LNRIO2-06
|
6
|
|
|
44Fxx12LNRIO2-12
|
12
|
|
|
Fxx24LNRIO2-24
|
24
|
|
|
|
|
|
|
Indoor Outdoor Loose Tube Riser Rated Fiber
Optic Wire Cable
Type OFNR Wires Cables Optical Wiring Cabling |
Prices are subject to change without
notice. Inventory is
subject to prior sale. Product design,
specifications & construction are subject
to change without notice. Pictures are for
general representational purposes and may not
represent actual product.
Not
Responsible for errors in print, verify all
data with us or manufacturer.
Terms & Conditions of sale apply, for a
copy contact us.
Products may be discontinued without notice.
Other disclaimers may apply.
*Minimum order quantities apply.